pISSN 2636-0004
eISSN 2636-0012

Download original image
Fig. 3. Migrated graft from the second case. (A, B) A greenish foreign body was identified in the hepatic flexure, attached to the deformed colonic wall by a thin thread. (C) The removed foreign body, measuring 7.5 cm, was identified as polytetrafluoroethylene graft material.
Int J Gastrointest Interv 2024;13:55~59 https://doi.org/10.18528/ijgii240012