This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Despite advancements in endoscopic retrograde cholangiopancreatography (ERCP), direct endoscopic visualization of the biliary tree by cholangioscopy is required to improve the diagnosis and treatment of the underlying disease. Although several types of peroral cholangioscopy (POC) systems are available, single-operator cholangioscopy (SOC) has been widely used for interventions in the biliary system. The first SOC was SpyGlass direct visualization system (Boston Scientific, Natick, MA, USA) expanded to a digital version of the SOC (SpyGlass DS; Boston Scientific). More recently, single-operator direct POC using an ultra-slim upper endoscope has been proposed. The remarkable developments in POC and available specialized accessories continue to improve therapeutic procedure of the biliary diseases. POC allows the visualization of bile duct stone and guide wire placement across difficult strictures and selective cannulation of the intrahepatic and cystic ducts. It is also demonstrating its utility in investigational applications such as intraductal ablation therapy for bile duct tumors, removal of foreign body in the bile duct and evaluation of hemobilia.
Keywords: Cholangioscopy, Lithotripsy, Photodynamic therapy, Radiofrequency ablation
Endoscopic retrograde cholangiopancreatography (ERCP) is a standard diagnostic and therapeutic procedure for biliary diseases. However, cholangiography alone has limitations for the management of some clinical situations. Cholangioscopy is a useful tool to overcome these limitations of ERCP allowing direct endoscopic visualization of biliary tree. Peroral cholangioscopy (POC) is traditionally only conducted using a mother-baby scope system. However, routine clinical application of this system has been restricted because of their fragility and requirement of the participation of two skilled endoscopists using 2 endoscopic systems.1,2 Subsequently, POC systems operated by single-operator have been introduced to overcome drawbacks of a mother-baby scope system. The first single-operator cholangioscopy (SOC) was SpyGlass direct visualization system (Boston Scientific, Natick, MA, USA) expanded to a digital version of the SOC (SpyGlass DS; Boston Scientific). More recently, single-operator direct POC using a conventional ultra-slim upper endoscope has been proposed. The remarkable developments in POC, such as image quality, technical convenience, and available specialized accessories, continue to improve real time diagnosis and therapeutic procedure of the biliary diseases. This review summarizes the role of POC in the therapeutic applications of biliary diseases with a focus on SOC.
SpyGlass direct visualization system was introduced as a SOC technique in 2007. The first version of SpyGlass system (referred to as ‘SpyGlass Legacy’) is composed of a reusable 0.77-mm diameter optical probe (6,000-pixel image with 70° field of view) and a disposable 10-Fr delivery catheter (SpyScvope; Boston Scientific). The delivery catheter has a fourway deflected steering, a 1.2-mm accessory channel, a 0.9-mm channel for the optical probe, and 2 dedicated 0.6-mm irrigation channels, which enables continuous water irrigation for clear image. However, SpyGlass Legacy has several limitations. The image quality was suboptimal, image stability was poor because of interference from blood and mucus, and manipulation of the catheter was challenging because of lack of coordination between the directional control dial movements and optical fiber visualization.3
In 2015, a digital version of SOC (SpyGlass DS; Boston Scientific) was introduced. The system consists of a fully integrated SpyScope Digital System Access and Delivery Catheter and a fully-disposable system to eliminate probe reprocessing. The integrated digital sensor provides superior imaging, greater resolution, and a 110° field of view. The insertion tube contains 1 working channel (1.2-mm diameter) for accessory devices and aspiration, 2 channels for irrigation, 2 optical fibers to transmit illumination from the controller, and wiring to transmit video signals to the controller. In addition, SpyGlass DS is easy to set up and the tapered distal end enables easy entering of the common bile duct (CBD)—using a free-hand technique or over a guidewire.4 Accessories for use with both the legacy and the SpyGlass DS systems include an intraductal mini-biopsy forceps (SpyBite; Boston Scientific). Recently, the next version of the SpyGlass DS system (SpyGlass DS version 2.0) has been released. It is expected to provide improved diagnostic and therapeutic capabilities using four-fold higher image resolution and optimized light emitting diode (LED) illumination.
During the direct POC, ultra-slim upper endoscope is directly inserted into the bile duct through the papilla. The ultra-slim endoscope was originally designed for use in pediatric patients and transnasal applications. Direct POC can be performed only after a large previous endoscopic sphincterotomy and/or sphincteroplasty, because the outer diameters are 5 to 6 mm, and the diameter of the CBD is usually > 8 mm. Ultra-slim endoscopes have working channels ranging from 2.0 to 2.2 mm which allow to extend interventional procedures, including for tissue sampling, and it permits the use of 5-Fr instruments. In addition, this system provides high-quality endoscopic imaging with the ease of performance of enhanced endoscopy by using narrow-band imaging or i-SCAN.1,4,5
However, advancement of an ultra-slim endoscope into the biliary tree has been a major limitation to the performance of direct POC because of acute angulation of biliary tree from second part of the duodenal lumen. Several specialized accessories and techniques are used to advance an ultra-slim endoscope into the proximal CBD.1,6–8 Although these accessories have improved the success rate of direct POC, it was still time-consuming and technically difficult to perform.9 Recently, a prototype multibending (MB) ultra-slim endoscope was introduced as a dedicated cholangioscope to overcome the technical difficulties of direct POC. The MB endoscope is a modified ultra-slim endoscope that can be inserted directly into the bile duct without using device assistance (“free-hand”). It has 2 bending sections and the outer diameters of the distal end and shaft of an MB endoscope are 4.9 mm and 7.0 mm, respectively, to improve pushability of the endoscope and to minimize loop formation in the stomach. The MB endoscope revealed a higher technical success rate than the conventional ultra-slim endoscope in free-hand biliary insertion of the endoscope for direct POC (89.1% vs 30.4%;
Management of difficult bile duct stones is most popular application of POC. Standard endoscopic stone-removal techniques, including mechanical lithotripsy, fails in 10%–15% of patients.11 Intracorporeal lithotripsy, such as electrohydraulic lithotripsy (EHL) or laser lithotripsy (LL) is a main treatment option for difficult bile duct stones. POC enables to conduct EHL or LL (Fig. 1) under direct visual control for safe and precise targeting during fragmentation. In a meta-analysis of 35 studies with 1,762 participants, POC with intraductal lithotripsy showed an overall stone fragmentation success of 91.2% with an average of 1.3 lithotripsy sessions performed. Complete single session fragmentation success was 76.9%. There was no difference in overall fragmentation rate or adverse events; however, LL was associated with a higher single-session fragmentation rate and shorter procedure time compared with EHL.12
In randomized controlled trials (RCTs), SOC-guided lithotripsy was compared with conventional endoscopic therapies for management of difficult bile duct stone. SpyGlass DVS-guided LL achieved a higher endoscopic clearance rate than conventional therapy only (93% vs 67%;
Although SOC-guided lithotripsy is effective and feasible procedure, it is considered to have several limitations in terms of cost, complexity and procedure time.16 Buxbaum et al13 reported mean procedure time of the SOC-guided LL (120.7 ± 40.2 minutes) was significantly longer than that of the conventional therapy (120.7 vs 81.2 minutes,
Another advantage of POC-guided lithotripsy is a potential to reduce radiation exposure of patients and endoscopist. In a previous study, radiation exposure of patients was significantly higher in the mechanical lithotripsy group than in the LL group (40,745 vs 20,989 mGycm2;
POC provides visual guidance for effective and safe ablation therapy of intraductal biliary tumor. POC may be useful for determining the extent of tumor and the appropriate location of the ablation catheter. In addition, it allows to evaluate effectiveness, remnant intraductal tumor, or recurrence after ablation therapy.1
Endobiliary radiofrequency ablation (RFA) for malignant biliary stricture (MBS) has been reported to contribute to obtaining longer stent patency or survival.18–21 However, endobiliary RFA under ERCP guidance has been associated with a high adverse event rate. A recent study evaluated the feasibility and safety of the RFA procedure using SpyGlass DS. In 12 patients with bile duct cancer, POC was performed before and after RFA, and endobiliary RFA was also applied under POC guidance. POC-guided RFA was technically successful in all patients and one adverse event (post-procedure cholangitis) was developed.22 Photodynamic therapy (PDT) also can be performed under POC guidance. Choi et al23 reported the feasibility and safety of direct POC-guided PDT (Fig. 2) in 9 patients with inoperable extrahepatic cholangiocarcinoma.
POC facilitates selective guidewire placement into the complicated biliary stricture or cystic duct (Fig. 3) that is difficult to approach by only conventional fluoroscopy. In previous study, SpyGlass DS-guided guidewire placement across complex biliary stricture was tried in 30 procedures of 23 patients with previously failed conventional guidewire placement. It was successful in 21 of 30 procedures (70%).24
The 2.0 to 2.2 mm working channel of an ultra-slim endoscope enable direct stent placement with a 5 to 6 Fr diameter stent after selective guidewire placement.6,10,25 During the direct POC, biliary stenting is possible to prevent cholangitis without exchanging the endoscope for a duodenoscope.
Small bile duct stones which were missed by conventional ERCP can be founded and removed under POC using baskets or other accessories (Fig. 4).26 In addition, POC has been described to successfully retrieve proximally migrated biliary stents or bile duct foreign body.27,28 Hemobilia could also be diagnosed and managed successfully by POC.29
With the development of more advanced cholangioscopic system, POC is becoming increasingly utilized as an effective tool for patients with biliary diseases. Therapeutic applications of POC for biliary lesions is also expanded owing to continuing advances in specialized endoscopes and available dedicated accessories. Nevertheless, current POC systems are still required improvement in terms of technical difficulty, diameter of working channel, available devices and cost.