IJGII Inernational Journal of Gastrointestinal Intervention

pISSN 2636-0004 eISSN 2636-0012
ESCI
scopus

Article

home All Articles View

Review Article

Gastrointestinal Intervention 2016; 5(1): 47-51

Published online March 31, 2016 https://doi.org/10.18528/gii150004

Copyright © International Journal of Gastrointestinal Intervention.

Interventional radiologic approach to hilar malignant biliary obstruction

Dong Il Gwon

Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea

Correspondence to:*Corresponding author. Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea. E-mail address:radgwon@amc.seoul.kr (D.I. Gwon).

Received: May 26, 2015; Revised: July 14, 2015; Accepted: July 14, 2015

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Biliary obstruction due to advanced hepatic hilar malignancy is difficult to treat, both surgically and non-surgically, using endoscopic or percutaneous drainage. Since only about 10% to 20% of patients are eligible for resection of hepatic hilar malignancies, most patients receive palliative rather than curative treatment. Percutaneous palliation of advanced hepatic hilar malignancies can be accomplished in a variety of ways. Percutaneous bilateral metallic stent placement may be a reasonable option in patients with hilar malignancies to preserve the functional volume of the liver during the course of chemotherapy and to prevent procedure-related cholangitis of a contaminated undrained lobe. Percutaneous bilateral stent-in-stent placement using wide-mesh or open-cell design stents is a feasible and effective method of achieving bilateral drainage. Moreover, unilateral covered or uncovered metallic stent placement in the lobe with patent portal vein is safe and effective method for palliative treatment in patients with contralateral portal vein occlusion caused by hilar malignancies, obviating the need for bilateral stent placement in these patients.

Keywords: Bile ducts, intrahepatic, Malignancy, Percutaneous, Stents

Biliary obstruction due to advanced hepatic hilar malignancy is difficult to treat, both surgically and non-surgically, using endoscopic or percutaneous drainage. Since only about 10% to 20% of patients are eligible for resection of hepatic hilar malignancies,1,2 most patients receive palliative rather than curative treatment.

A percutaneous approach can be a reasonable option to treat malignant hilar obstruction and is often the most appropriate management. Previous studies reported that percutaneous approaches had a higher technical/clinical success rate and lower incidence of infective complications compared with endoscopic approaches.35 Percutaneous palliation of advanced hepatic hilar malignancies can be accomplished in a variety of ways.618 The author therefore reviews percutaneous techniques for the treatment of hilar malignant biliary obstruction.

There have been conflicting opinions as to whether stent placement should be unilateral or bilateral.6,7,1924 Some investigators have preferred bilateral stenting not only because unilateral stenting alone may not completely relieve jaundice22 and may induce acute cholangitis7 but also because stent patency may be longer than unilateral stenting.6 On the other hand, others have advocated unilateral drainage not only because the risk of complications is lower than multiple stent deployment20 but also because adequate palliation can be achieved by the drainage of only 25% of the liver.24 In a report by De Palma et al,19 patients with bilateral drainage had a significantly lower rate of successful stent insertion and a significantly higher rate of early cholangitis than patients with unilateral drainage. However, these previous reports have usually focused on technical or clinical outcomes of unilateral or bilateral drainage in advanced hilar obstruction according to Bismuth-Corlette classification.

Although it is unclear whether drainage of both liver lobes in patients with Bismuth type II or higher malignant hilar tumors is necessary, to preserve the functional volume of the liver during the course of chemotherapy and to prevent procedure-related cholangitis of a contaminated undrained lobe,6,7,1923 bilateral drainage may be a reasonable option. Bilateral biliary drainage can be accomplished by the percutaneous placement of multiple stents.618

Palliative stent placement for advanced hilar malignancies is usually accomplished through two separate transhepatic punctures in a Y configuration, X configuration or single transhepatic puncture in a T configuration.618 Two techniques have been developed for the percutaneous placement of bilateral metallic stents, side-by-side and stent-in-stent deployment techniques. The side-by-side deployment technique results in the simultaneous insertion of two parallel metallic stents to drain the bile ducts of both hepatic lobes (Fig. 1). This parallel arrangement, however, may prevent full expansion of metallic stents at and below the hepatic confluence.9 Although adequate drainage may be achieved, expansion of the stents to less than their full diameter may result in stent elongation or partial collapse of one or both stents.

Recently, bilateral drainage using the partial stent-in-stent deployment procedure has been reported.9,1013,15,17 In the stent-in-stent deployment technique, a second stent is placed through the mesh of the first stent to enter the common bile duct (Fig. 2). Using this technique, the entire length of the stricture can continuously expand within a single stent caliber, a result that cannot be achieved using the side-by-side stent deployment technique. Moreover, overlapping of the two stents can effectively prevent displacement of the stents. However, passing a second metallic stent through the mesh of the first stent can be technically difficult if the first stent has a tightly woven closed-cell-design.25 To overcome the technical difficulties associated with the stent-in-stent deployment technique using closed-cell-design stents, some investigators adopted two types of metallic stents, of wide-mesh and open-cell design stents, as first stents and determined that both types performed equally well in bilateral stent-in-stent deployment.1013,15,17

The wide-mesh-design stent has a wider central mesh portion, permitting easy passage of the delivery system for the second stent. In a report by Kim et al,10 the creation of a true T configuration using wide-mesh first stent was preferable to other approaches as it offered a large luminal diameter throughout the mesh of the first stent and that overlapping two stents was effective in preventing their displacement. The cells of the open-cell-design stents are connected more easily than the tight weaving and interlocking of other closed-cell-design stents.15,17 Thus, open-cell-design stents can be dilated easily by ballooning and remain dilated, thus permitting easy passage of the second stent during bilateral stenting and its wide expansion. Moreover, open-cell-design stents could be easily navigated through the tortuous strictures due to their low profile delivery system and high flexibility. Despite a paucity of percutaneous studies, there were no significant between group differences in stent occlusion rate and stent patency period.15,17 Moreover, there were no significant differences between the wide-mesh and open-cell design stent groups in technical success, complications, successful internal drainage, and patient survival.17 To achieve bilateral drainage in patients with stent occlusion, reintervention was more easily performed in patients in whom stents had been inserted in a T than in a Y configuration.17 Therefore, T-configured stent-in-stent deployment for bilateral drainage may be preferable in patients with malignant hilar biliary obstruction unless technical difficulties necessitate Y-configured stent-in-stent deployment.17

In previous studies using percutaneous bilateral stenting, the technical success rate ranged from 93% to 100%, the overall complication rate ranged from 0% to 7.7%, the successful internal drainage rate ranged from 87.5% to 92%, the median stent patency time ranged from 170 to 275 days, and the median patient survival time ranged from 126 to 299 days (Table 1).10,11,15,17 Multiple stent placement can be a reasonable option in the patients who are anicteric with a high-grade hilar stricture and cholangitic after bilateral stent placement (Fig. 3).

The indications for percutaneous unilateral biliary stent placement are no/little functional liver parenchyma due to huge tumor and unilateral portal vein occlusion with/without subsequent hepatic lobar atrophy due to hilar or parenchymal tumor. In general, the most important factor in regulating the volume of bile flow is the rate of bile salt synthesis by hepatocytes, which is regulated by the return of bile salts to the liver through enterohepatic circulation. When the portal vein of one liver lobe is obstructed, portal vein obstruction interrupts the cycle of enterohepatic circulation in the obstructed lobe.13 Previous investigators reported successfully treating bile leakage by performing selective portal vein embolization, which induces cessation of bile production.26,27 Thus, the liver lobe with portal vein occlusion caused by advanced hilar malignancies ceases to produce bile and becomes nonfunctional and atrophied. Hepatic lobar atrophy is a frequent accompaniment of hilar cholangiocarcinoma and has been reported to occur in 20% to 30% of patients with that diagnosis.28,29 Hepatic lobar atrophy usually occurs in the setting of combined biliary and portal vein occlusion, which is most frequently ipsilateral to the atrophic lobe. Moreover, previous studies have reported a significant correlation between hepatic lobar atrophy and ipsilateral portal vein occlusion and that unilateral portal vein occlusion in the atrophied lobe was present in 87% to 100% of patients.28,29

To date, there has been only one radiologic comparative study of unilateral and bilateral stenting in patients with hilar biliary obstruction with unilobar portal vein occlusion caused by advanced malignancies.13 In a report by Gwon et al,13 unilateral biliary metallic stent placement in the lobe with patent portal vein seemed to be a safe and effective palliative treatment of patients with contralateral portal vein occlusion caused by advanced hilar malignancy, obviating bilateral stent placement in these patients, because the hepatic lobe with portal vein occlusion caused by advanced hilar malignancies ceases to produce bile due to interruption of enterohepatic circulation. In the study, during the follow-up period, the intrahepatic bile ducts of the undrained lobe with portal vein occlusion in patients who underwent unilateral biliary stent placement showed a slight decrease in diameter on follow-up computed tomography, which means bile production in the undrained lobe may be functionally impaired or ceased by bile duct obstruction as well as portal vein occlusion (Fig. 4).

The use of covered stents in the biliary system was initially developed to address the issue of tumor ingrowth. Recently, the use of polytetrafluoroethylene (PTFE)-covered stents has been found to be an effective treatment method, with the PTFE material serving as an effective barrier to prevent tumor ingrowth.3033 In one comparative study of PTFE-covered and uncovered stents,34 PTFE-covered stents were significantly superior to uncovered stents in terms of stent patency.

In general, one important limitation in using covered stent for treatment of malignant hilar biliary obstruction is a risk of occlusion of branching intrahepatic bile duct. Interestingly, in the previous studies, PTFE-covered stents for palliative treatment of malignant hilar biliary obstruction prevented tumor ingrowth without functional occlusion of the hepatic segmental bile ducts.12,14 The branching intrahepatic bile ducts blocked by the covered stents showed a significant diameter decrease on the follow-up computed tomographic images and the serum bilirubin level also decreased significantly. In a report by Yi et al,35 unilateral placement of PTFE-covered stents in the hepatic lobe with a patent portal vein was a safe and effective method for palliative treatment of patients with contralateral portal vein occlusion caused by advanced hilar malignancies (Fig. 5). Although a covered stent could effectively prevent stent dysfunction caused by tumor ingrowth, covered stent dysfunction was mainly caused by sludge incrustation. Further investigations will be required in order to determine how to decrease the incidence of sludge formation.

In conclusion, percutaneous bilateral stenting may be a reasonable option in patients with hilar malignancies to preserve the functional volume of the liver during the course of chemotherapy and to prevent procedure-related cholangitis of a contaminated undrained lobe. Percutaneous bilateral stent-in-stent placement using wide-mesh or open-cell design stents is a feasible and effective method of achieving bilateral drainage in patients with malignant hilar biliary obstruction. Moreover, unilateral covered or uncovered metallic stent placement in the lobe with patent portal vein is safe and effective method for palliative treatment in patients with contralateral portal vein occlusion caused by advanced hilar malignancies, obviating the need for bilateral biliary stent placement in these patients. The author’s percutaneous approach to treatment of patients with hilar malignant biliary obstruction was summarized in Fig. 6.

Fig. 1. Side-by-side deployment technique (Y configuration) for bilateral drainage. (A) Note simultaneous insertion of two stent endoprostheses from intrahepatic bile duct of both hepatic lobes to common bile ducts. (B) Cholangiogram after deployment shows successful Y-configured stent placement using two close-cell-design stents. Note right-sided stent (black arrows) and left-sided stent (white arrows).
Fig. 2. Stent-in-stent deployment technique (T configuration) for bilateral drainage. (A) Cholangiogram shows a malignant hilar obstruction. (B) After inserting the first transverse stent from right to left hepatic duct, the guide wire for second stenting was successfully inserted into common bile duct through the mesh of the first stent (arrow). (C) Cholangiogram shows successful deployment of the second stent from the left side into the common bile duct through the mesh of the first stent.
Fig. 3. Multiple stent deployment due to anatomic variation. (A) After inserting of two stents in a T configuration from left side to right anterior and common bile duct, a 5-F catheter (arrowheads) was successfully inserted from right posterior duct to common bile duct. (B) Cholangiogram shows successful deployment of the third stent (arrows) from right posterior duct to common bile duct through the mesh of the first stent.
Fig. 4. Computed tomographic images obtained before percutaneous transhepatic biliary drainage (A) and two months after unilateral stent placement (B) in a 75-year-old man with cholangiocarcinoma and right portal vein occlusion show little diameter change of left intrahepatic bile duct after right-sided unilateral stent placement (arrow).
Fig. 5. Unilateral covered stent placement in a 83-year-old man with intrahepatic cholangiocarcinoma and right portal vein occlusion. (A) Computed tomographic image shows intrahepatic bile duct dilatation and right portal vein occlusion (arrow) caused by intrahepatic cholangiocarcinoma (asterisk). (B) Cholangiogram via the left-sided catheter shows occlusion of the left intrahepatic bile duct and upper common bile duct. Right intrahepatic bile duct is not opacified by contrast media. (C) Cholangiogram 3 days after polytetrafluoroethylen-covered stent placement shows good passage of contrast media through the stent (arrows).
Fig. 6. Author’s treatment algorithm of hilar malignant biliary obstruction. CT, computed tomography; MR, magnetic resonance; PV, portal vein; PTBD, percutaneous transhepatic biliary drainage.

Studies Involving Percutaneous Bilateral Stenting for Hilar Malignant Biliary Obstruction

StudyNumber of patientsCompanyType of stentNumber of stentTechnical success (%)Stent patency (day, median)Patient survival (day, median)
Kim et al10 (2004)57Taewoong MedicalKim stent & Niti-S114100170.3193.6
Bae et al11 (2008)42Taewoong MedicalKim stent & Niti-D8298187247
Ahn et al15 (2012)26Boston ScientificSentinol5993191.8299
Gwon et al17 (2013)106Cook, Boston ScientificZilver, Sentinol212100319192
  1. Bismuth, H, Castaing, D, and Traynor, O (1988). Resection or palliation: priority of surgery in the treatment of hilar cancer. World J Surg. 12, 39-47.
    Pubmed CrossRef
  2. Ogura, Y, Mizumoto, R, Tabata, M, Matsuda, S, and Kusuda, T (1993). Surgical treatment of carcinoma of the hepatic duct confluence: analysis of 55 resected carcinomas. World J Surg. 17, 85-92.
    Pubmed CrossRef
  3. Saluja, SS, Gulati, M, Garg, PK, Pal, H, Pal, S, and Sahni, P (2008). Endoscopic or percutaneous biliary drainage for gallbladder cancer: a randomized trial and quality of life assessment. Clin Gastroenterol Hepatol. 6, 944-50.
    Pubmed CrossRef
  4. Walter, T, Ho, CS, Horgan, AM, Warkentin, A, Gallinger, S, and Greig, PD (2013). Endoscopic or percutaneous biliary drainage for Klatskin tumors?. J Vasc Interv Radiol. 24, 113-21.
    CrossRef
  5. Paik, WH, Park, YS, Hwang, JH, Lee, SH, Yoon, CJ, and Kang, SG (2009). Palliative treatment with self-expandable metallic stents in patients with advanced type III or IV hilar cholangiocarcinoma: a percutaneous versus endoscopic approach. Gastrointest Endosc. 69, 55-62.
    CrossRef
  6. Inal, M, Akg?l, E, Aksungur, E, and Seydao?lu, G (2003). Percutaneous placement of biliary metallic stents in patients with malignant hilar obstruction: unilobar versus bilobar drainage. J Vasc Interv Radiol. 14, 1409-16.
    Pubmed CrossRef
  7. Cowling, MG, and Adam, AN (2001). Internal stenting in malignant biliary obstruction. World J Surg. 25, 355-9.
    Pubmed CrossRef
  8. LaBerge, JM, Doherty, M, Gordon, RL, and Ring, EJ (1990). Hilar malignancy: treatment with an expandable metallic transhepatic biliary stent. Radiology. 177, 793-7.
    Pubmed CrossRef
  9. Kubota, Y, Nakatani, S, Nakahashi, Y, Takaoka, M, Kin, H, and Inoue, K (1993). Bilateral internal biliary drainage of hilar cholangiocarcinoma with modified Gianturco Z stents inserted via a single percutaneous tract. J Vasc Interv Radiol. 4, 605-10.
    Pubmed CrossRef
  10. Kim, CW, Park, AW, Won, JW, Kim, S, Lee, JW, and Lee, SH (2004). T-configured dual stent placement in malignant biliary hilar duct obstructions with a newly designed stent. J Vasc Interv Radiol. 15, 713-7.
    Pubmed CrossRef
  11. Bae, JI, Park, AW, Choi, SJ, Kim, HP, Lee, SJ, and Park, YM (2008). Crisscross-configured dual stent placement for trisectoral drainage in patients with advanced biliary hilar malignancies. J Vasc Interv Radiol. 19, 1614-9.
    Pubmed CrossRef
  12. Gwon, DI, Ko, GY, Yoon, HK, Kim, JH, Lee, JM, and Ohm, JY (2010). Prospective evaluation of a newly designed T-configured stent graft system for palliative treatment of advanced hilar malignant biliary obstructions. J Vasc Interv Radiol. 21, 1410-8.
    Pubmed CrossRef
  13. Gwon, DI, Ko, GY, Sung, KB, Yoon, HK, Shin, JH, and Hyoung Kim, J (2011). Percutaneous biliary metallic stent placement in patients with unilobar portal vein occlusion caused by advanced hilar malignancy: outcome of unilateral versus bilateral stenting. AJR Am J Roentgenol. 197, 795-801.
    Pubmed CrossRef
  14. Gwon, DI, Ko, GY, Yoon, HK, Kim, YJ, Kim, TH, and Lee, WH (2012). Safety and efficacy of percutaneous Y-configured covered stent placement for malignant hilar biliary obstruction: a prospective, pilot study. J Vasc Interv Radiol. 23, 528-34.
    Pubmed CrossRef
  15. Ahn, SJ, Bae, JI, Han, TS, Won, JH, Kim, JD, and Kwack, KS (2012). Percutaneous biliary drainage using open cell stents for malignant biliary hilar obstruction. Korean J Radiol. 13, 795-802.
    Pubmed KoreaMed CrossRef
  16. Kang, BC, Lee, SW, and Chung, HH (2013). A newly designed Y-shaped covered stent in the palliative treatment of hepatic hilar malignant obstruction: case report. Korean J Radiol. 14, 97-101.
    Pubmed KoreaMed CrossRef
  17. Gwon, DI, Ko, GY, Kim, JH, Shin, JH, Kim, KA, and Yoon, HK (2013). Percutaneous bilateral metallic stent placement using a stentin-stent deployment technique in patients with malignant hilar biliary obstruction. AJR Am J Roentgenol. 200, 909-14.
    Pubmed CrossRef
  18. Li, TF, Li, Z, Han, XW, Ren, JZ, Jiao, C, and Bi, YH (2014). Combined T/Y biliary stent placement for the treatment of biliary obstruction caused by Bismuth-Corlett type IV hilar cholangiocarcinoma. Hepatogastroenterology. 61, 1519-22.
    Pubmed
  19. De Palma, GD, Pezzullo, A, Rega, M, Persico, M, Patrone, F, and Mastantuono, L (2003). Unilateral placement of metallic stents for malignant hilar obstruction: a prospective study. Gastrointest Endosc. 58, 50-3.
    Pubmed CrossRef
  20. Polydorou, AA, Cairns, SR, Dowsett, JF, Hatfield, AR, Salmon, PR, and Cotton, PB (1991). Palliation of proximal malignant biliary obstruction by endoscopic endoprosthesis insertion. Gut. 32, 685-9.
    Pubmed KoreaMed CrossRef
  21. Burke, DR, and McLean, GK (1989). Obstructions of the hepatic duct confluence: internal drainage of bilateral lesions with a single catheter. Radiology. 172, 1035-8.
    Pubmed CrossRef
  22. Chang, WH, Kortan, P, and Haber, GB (1998). Outcome in patients with bifurcation tumors who undergo unilateral versus bilateral hepatic duct drainage. Gastrointest Endosc. 47, 354-62.
    Pubmed CrossRef
  23. Naitoh, I, Ohara, H, Nakazawa, T, Ando, T, Hayashi, K, and Okumura, F (2009). Unilateral versus bilateral endoscopic metal stenting for malignant hilar biliary obstruction. J Gastroenterol Hepatol. 24, 552-7.
    Pubmed CrossRef
  24. Adam, A (1994). Metallic biliary endoprostheses. Cardiovasc Intervent Radiol. 17, 127-32.
    Pubmed CrossRef
  25. Silverman, W, and Slivka, A (1996). New technique for bilateral metal mesh stent insertion to treat hilar cholangiocarcinoma. Gastrointest Endosc. 43, 61-3.
    Pubmed CrossRef
  26. Yamakado, K, Nakatsuka, A, Iwata, M, Kondo, A, Isaji, S, and Uemoto, S (2002). Refractory biliary leak from intrahepatic biliary-enteric anastomosis treated by selective portal vein embolization. J Vasc Interv Radiol. 13, 1279-81.
    Pubmed CrossRef
  27. Sadakari, Y, Miyoshi, A, Ohtsuka, T, Kohya, N, Takahashi, T, and Matsumoto, K (2008). Percutaneous transhepatic portal embolization for persistent bile leakage after hepatic resection: report of a case. Surg Today. 38, 668-71.
    Pubmed CrossRef
  28. Hann, LE, Getrajdman, GI, Brown, KT, Bach, AM, Teitcher, JB, and Fong, Y (1996). Hepatic lobar atrophy: association with ipsilateral portal vein obstruction. AJR Am J Roentgenol. 167, 1017-21.
    Pubmed CrossRef
  29. Takayasu, K, Muramatsu, Y, Shima, Y, Moriyama, N, Yamada, T, and Makuuchi, M (1986). Hepatic lobar atrophy following obstruction of the ipsilateral portal vein from hilar cholangiocarcinoma. Radiology. 160, 389-93.
    Pubmed CrossRef
  30. Schoder, M, Rossi, P, Uflacker, R, Bezzi, M, Stadler, A, and Funovics, MA (2002). Malignant biliary obstruction: treatment with ePTFE-FEP-covered endoprostheses initial technical and clinical experiences in a multicenter trial. Radiology. 225, 35-42.
    Pubmed CrossRef
  31. Hatzidakis, A, Krokidis, M, Kalbakis, K, Romanos, J, Petrakis, I, and Gourtsoyiannis, N (2007). ePTFE/FEP-covered metallic stents for palliation of malignant biliary disease: can tumor ingrowth be prevented?. Cardiovasc Intervent Radiol. 30, 950-8.
    Pubmed CrossRef
  32. Han, YM, Kwak, HS, Jin, GY, Lee, SO, and Chung, GH (2007). Treatment of malignant biliary obstruction with a PTFE-covered self-expandable nitinol stent. Korean J Radiol. 8, 410-7.
    Pubmed KoreaMed CrossRef
  33. Gwon, DI, Ko, GY, Sung, KB, Yoon, HK, Shin, JH, and Kim, JH (2011). A novel double stent system for palliative treatment of malignant extrahepatic biliary obstructions: a pilot study. AJR Am J Roentgenol. 197, W942-7.
    Pubmed CrossRef
  34. Gwon, DI, Ko, GY, Kim, JH, Yoon, HK, Lee, IS, and Kim, KA (2010). A comparative analysis of PTFE-covered and uncovered stents for palliative treatment of malignant extra-hepatic biliary obstruction. AJR Am J Roentgenol. 195, W463-9.
    Pubmed CrossRef
  35. Yi, R, Gwon, DI, Ko, GY, Yoon, HK, Kim, JH, and Shin, JH (2012). Percutaneous unilateral placement of biliary covered metallic stent in patients with malignant hilar biliary obstruction and contralateral portal vein occlusion. Acta Radiol. 53, 742-9.
    Pubmed CrossRef