Gastrointestinal Intervention 2018; 7(1): 18-20
Published online April 30, 2018 https://doi.org/10.18528/gii180007
Copyright © International Journal of Gastrointestinal Intervention.
Harry Trieu, and Edward Wolfgang Lee*
Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
Correspondence to: Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, 757 Westwood Plaza, Suite 2125, Los Angeles, CA 90095, USA.
This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Initial underdilation of transjugular intrahepatic portosystemic shunt (TIPS) stents has been a widely proposed and commonly practiced technique to balance portal hypertension relief and the adverse effects associated with excess shunting, especially hepatic encephalopathy. However, this technique has been scrutinized by a number of studies which have shown that underdilated TIPS stents tend to passively expand with time. The recently launched GORE® VIATORR® TIPS Endoprosthesis with Controlled Expansion (VIATORR CX®) may address this problem with its novel diameter control capabilities. This article reviews literature concerning passive expansion of initially underdilated TIPS stents and explores preliminary data investigating the use and efficacy of the VIATORR CX® endoprosthesis.
Keywords: Hypertension, portal, Transjugular intrahepatic portosystemic shunt, Transjugular intrahepatic portosystemic shunt patency
Transjugular intrahepatic portosystemic shunt (TIPS) has been used extensively to treat portal hypertension and its complications.1 However, TIPS placement causes a decrease in portosystemic pressure gradient (PSG), which has been associated with complications such as hepatic encephalopathy (HE) and deterioration of liver function.2 Initial underdilation of the TIPS stent is commonly practiced in order to balance portal hypertension relief and the adverse effects associated with excessive shunting.2–6 Despite this, multiple studies have shown that intentionally underdilated stents passively expand over time, raising questions about the effectiveness of this technique.7–12 The recently released GORE® VIATORR® TIPS Endoprosthesis with Controlled Expansion (VIATORR CX®) aims to address this issue by preventing self-expansion and allowing for constant TIPS diameter as intended.11 In this review, we summarize the literature on passive expansion of underdilated TIPS stents. We then introduce the VIATORR CX® stent and explore preliminary data from a study and a case report investigating its use and efficacy.
Passive expansion of initially underdilated TIPS stents is a well-documented phenomenon with the first reports dating back to 1994.7 It is thought that passive expansion occurs when the expansive forces of the TIPS stent overcomes the compressive forces of the cirrhotic liver. Haskal et al7 published a study in which 37 shunts were dilated using a 10-mm balloon. Immediately following shunt placement, 19 shunts measured 8.3 ± 1.2 mm (mean ± standard deviation) due to recoiling of stents. At follow-up in 3 to 6 months, 89% of stents had expanded to near 10 mm (9.8 ± 0.4 mm). Approximately ten years later, Gaba et al8 published a study in which 41 patients underwent TIPS creation with initial underdilation to 8.0 mm, while 20 patients had placement with initial expansion using a 10-mm balloon. Median stent diameter at follow-up in the underdilated group was 9.8 mm, which represented a significant increase from the 8.0 mm baseline diameter (
The first of two studies published by Pieper et al9 retrospectively investigated passive stent expansion in 39 patients who underwent TIPS creation using VIATORR and WallstentTM endoprostheses. VIATORR stent grafts and WallstentTM endoprostheses were initially underdilated to an average of 64.4% ± 2.3% and 65.63% ± 8.52% of nominal area, respectively. At the time of last follow-up, VIATORR and WallstentTM endoprostheses had significantly expanded to a mean of 87.8% ± 7.9% and 82.34% ± 19.6% of nominal area in the TIPS tract, respectively (
Borghol et al10 examined endoluminal stent diameter in 16 patients who underwent TIPS creation using a 10-mm VIA-TORR stent graft, underdilated at the time of placement. Mean endoluminal stent diameter, measured via angiography, significantly increased from 8.96 ± 1.12 mm to 10.00 ± 1.45 mm after 6 months (
In March of 2017, W. L. Gore & Associates, Inc. announced the U.S. Food and Drug Administration approval and U.S. launch of its GORE® VIATORR® TIPS Endoprosthesis with Controlled Expansion (VIATORR CX®).13 According to the manufacturer, VIATORR CX® allows interventionalists to finely tune stent diameter until the desired PSG is reached and set the diameter to stay. Benchtop data showed a maximal diameter increase of no more than 0.25 mm over a simulation period of 10 years at physiological portal pressures. Controlled expansion is enabled by the addition of a controlled expansion sleeve on the outside of the device (Fig. 1). The ePTFE sleeve limits the diameter of the self-expanding nitinol stent within the range of 8 to 10 mm. The sleeve can then be stretched with balloon dilatation under an inflation pressure of at least 10 atm to achieve the desired device diameter based on chosen balloon diameter. Delivery and deployment are unchanged.
Preliminary data from a case-control study demonstrated a reduction in post-procedure complications in patients who underwent TIPS creation using the VIATORR CX® endoprosthesis.14 The study compared 21 patients who underwent TIPS implantation using VIATORR CX® to 48 patients who received a regular covered VIATORR stent and 36 patients who received a bare metal stent (BMS). Patients were assessed at 7 days, 6 weeks, and 3 months following TIPS creation. MELD-Na score at 3 months was significantly improved in the VIATORR CX® group compared to the regular VIATORR and BMS groups (8 vs 11 vs 15;
Beyond its use in new TIPS creations, the VIATORR CX® endoprosthesis may also be well-suited for TIPS reductions. In a recent letter to the editor, Srinivasa et al15 described two patients who developed medically refractory HE following TIPS creation. Both patients underwent TIPS reduction using the VIATORR CX® endoprosthesis deployed to a diameter of 8 mm and experienced a 1-grade reduction in HE at follow-up. The authors point out that the VIATORR CX® is superior for TIPS reduction because it does not require the use of multiple stents and balloons, resulting in a shorter procedure time. That being said, the VIATORR CX® endoprosthesis is not commercially available in diameters smaller than 8 mm and this could represent a disadvantage if shunt reduction to 8 mm is insufficient for certain patients suffering from TIPS-related complications.
In summary, initial underdilation of TIPS stents is commonly performed to relieve portal hypertension, while circumventing the complications associated with excess shunting. However, this approach is problematic due to the tendency of legacy stents to passively expand over time. The newly released VIATORR CX® endoprosthesis may address this issue with its novel diameter control capabilities. Preliminary results from a study comparing the VIATORR CX® stent to legacy VIATORR and BMS shows a reduction in post-TIPS complications in patients who receive the VIATORR CX®. Further, the new stent allows for simpler TIPS reductions with shorter procedure times. Further studies are necessary to fully understand the benefits of the new VIATORR CX® stent; however, the preliminary data appear promising.
Authors’ contributions: H.T. and E.W.L. equally contributed to this paper with conception and design of the study, data collection and analysis, statistical analysis, literature review and analysis, drafting and critical revision and editing, and final approval of the final version.
No potential conflict of interest relevant to this article was reported.
© The Society of Gastrointestinal Intervention. Powered by INFOrang Co., Ltd.